Related Products |
|
|
|
|
|
| |
|
|
AS-Interface
Safety at Work |
|
AS-Interface, the recognized cabling system
for sensors and actuators, has been enhanced. Standard process information
and information relating to safety can now be transmitted over the
same yellow cable. Capable of managing safety functions up to category
4 of standard EN-954-1/ISO 13849-1 and conforming to SIL 3 of standard
IEC 61508, the AS-Interface “Safety
at work” system meets the needs of the most common safety monitoring
applications, such as:
- Emergency stops with instantaneous break
contacts (stop category 0)
- Emergency stops with delayed break contacts
(stop category 1)
- Safety interlocks and limit switches with and without
interlocking
- Light curtains, etc.
Features and Benefits
- • Safety
- Category 4 according to EN954-1
- SIL 3 according IEC 61508
- Simplicity
- just add the required safety devices to the standard AS-Interface
network
- Integration
- standard data and safety relevant data transmitted over the
same communication bus, i.e. no need for a separate safety network
- Flexibility
- monitor multiple devices and control multiple safety sectors
- Diagnose
- from one screen, see the status of the safety interfaces
and the system
- Multifunctional
- able to monitor up to 31 safety interfaces
- available with 1 or 2 independent output groups
- Segmentation of Safety Sectors
- multiple safety monitors can be connected to the monitors can be configured
to monitor different groups of safety interfaces
- Reduction in installation
time
- Saves 40% on installation cost
ASISAFEMON2 Monitor
- Choice of either
one or two independent output groups
- ASISAFEMON1B – 1
output group
- ASISAFEMON2B – 2 output groups
- Diagnostics can be shown on
PC via RJ45 connection on safety monitor or can be communicated to
the PLC via the AS-interface cable
- 45mm wide housing
ASISWIN2 Configuration Software
- Drag & Drop
methodology
- Predefined, certified safety functions for user selection
- Online
diagnostics of AS-Interface Safety System
- Password protection
- Logic functions
OR (up to 6 devices)
On delay/off delay/pulse, etc
- EDM (external device monitoring) - feedback
loop
- Start devices
automatic start
monitored start
- Output devices
stop category 1
stop category 0
- Able to configure up to 48 devices
Safety Interfaces
- Interfaces for emergency stop buttons
- ASISSLB4 for metal body emergency
stop buttons
- ASISSLB5 for plastic body emergency stop buttons
- Interfaces for direct connection via M16 thread
- ASISSLLS
- Interfaces for M12 connectors
- ASISSLC1 - single M12 connection
- ASISSLC2 - twin M12 connections
|
|
|
|
|
Copyright Schneider Electric. All Rights Reserved. |
|